The following link will lead to the publication that is online now. After more than a year in review process and some corrections, it is finally published.
http://www.tandfonline.com/doi/full/10.1080/14680629.2017.1281833
Showing posts with label luminescence spectroscopy. Show all posts
Showing posts with label luminescence spectroscopy. Show all posts
Thursday, 9 February 2017
Thursday, 14 January 2016
Investigation of bitumen ageing through bitumen separation and luminescence spectroscopy
This was the title of a short presentation and a poster presentation I have done last summer at a conference in Vienna.
The poster can be downloaded under the following link:
https://drive.google.com/file/d/0B65XBjxJe8sxclhndEI4Z2doZnc/view?usp=sharing
I am now currently working on a new different project, which has no direct connection to bitumen ageing. Hence, I won't post regular.
Tuesday, 3 March 2015
determining ageing by luminescence spectroscopy
Luminescence is the umbrella term for phosphorescence and fluorescence.
Each bitumen fraction has a unique features regarding its spectra. The main part of saturates exhibit less luminescence.
Aromatics exhibit the highest intensity, slowly decreasing forwards resins. The
decreasing intensity of bitumen over ageing is likely owned to the change in
the amount of aromatics. Resins and solid asphaltenes have two characteristic
peaks at about 536 nm and 605 nm, which too can be found for saturates, but at a lower intensity. Asphaltenes
in a solid state exhibit nearly no luminescence. In solution asphaltenes displays
a spectrum similar to aromatics, but with lowest intensity and due to the phenomenon that aspahltenes form stacks and agglomerate in solution, it is assumed that asphaltenes dissolved in maltenes emit a spectrum similar to solid asphaltenes.
![]() |
| normalized emission spectra (excitation at 280 nm) |
The figure shows the changes in the spectrum over the three ageing stages. Non-aged
bitumen (B) lacks the peaks typically for resins and asphaltenes, but
short-term aged (B_LRTFOT) and long-term aged (B_PAV and B_F282) exhibit these
peaks. Unfortunately there is not a correlation between peak intensity and
ageing stage. The different curve slopes, starting at about 340 nm, are
caused partially by normalizing of the spectra. Not normalized B, B_LRTFOT and
B_PAV spectra have the same starting slope, but differ in intensity maxima. Due
to normalization the maxima are the equal, yet the slope changes. So the maxima
or the slope can provide a hint to the ageing progress.
Subscribe to: